110
en | Programming
Siren / PO 1+2 Supervision
Address 0140
0 = disabled, 1 = PO1 enabled, 2 = PO2 enabled, 3 =
PO1+2 enabled
Keypad 2 Button Alarm
Address 0141
0 = disabled, 1 = enabled
Phone Line Monitor
Address 0142
0 = disabled, 1 = enabled
Beep For Warning Devices
Address 0143
0 = disabled, 1 = enabled
Ring Count
Address 0144
1 - 13 = Number of rings until the control panel responds
14 = Call the control panel and allow the phone to ring no
more than twice and hang up. Wait a minimum of 8 sec
and call the control panel again. The control panel
answers on the first ring.
15 = Call the control panel and allow the phone to ring no
more than four times and then hang up. If you call again
within 45 sec, the control panel answers the call on the
first ring.
0 = Panel does not answer
Remote Programming
Address 0145
0 = disabled, 1 = enabled
Callback Telephone Number
Address 0146 - 0161
See Telephone Programming Parameters
2013.07 | 03 | F.01U.267.112
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Address
Default
0140
0
VDS-A EN=3
Address
Default
0141
0
Address
Default
0142
0
VDS-A EN=1
Address
Default
0143
1
Address
Default
0144
14
Address
Default
0145
1
VDS-A=0
Address
Default
0146 - 0161
15
Bosch Sicherheitsysteme GmbH