Table 5.8: DX3010 DIP Switch Settings
Figure 5.9: DX3010 DIP Switch Settings
5.3.4

Test

The alarm control panel tests the communication normally with the module. In case of
communication failure, a fault report with the module address is sent.
5.4

B426 Network Interface Module

5.4.1

Brief Introduction

The B426 Ethernet communication module supports monitored two-way IP communication via
Ethernet to perform alarm transmission, remote programming and control of the alarm control
panel.
The alarm control panel supports up to two B426 modules.
5.4.2

Installation

Before installing B426, all power supplies (AC power supply and backup battery power
supply) of the control panel should be disconnected.
Use the standard three-hole installation mode to install B426 in the enclosure of the alarm
control panel case or in another enclosure.
For more information about installation, see B426 Installation and Operating Guide.
Also refer to , page 28 for more details.
5.4.3

Wiring

Connect B426 to Bosch option Bus 1 or 2. The cable may not exceed 150 meters.
Bosch Sicherheitsysteme GmbH
On
Off
Example : Data Bus Location 150 - DIP Settings
Optional Modules and Peripheral Devices | en
On
On
On
On
Off
Installation Guide
On
On
On
On
On
2013.07 | 03 | F.01U.267.112