Bosch AMAX panel 4000 Installation Manual page 52

Icp-amax4-p1 / icp-amax4-p2-en / icp-amax-p3-en
Hide thumbs Also See for AMAX panel 4000:
Table of Contents

Advertisement

52
en | Settings
Zone normal: Activate Disarm
Wiring Diagram for Key-switch Zone: short for arm. The momentary time is capable of lasting
Min. 300ms.
Wiring Diagram for Key-switch Zone: short for arm. The momentary time is capable of lasting
Min. 300ms.
When the key-switch operates the Arm/Disarm, the keypad sounds two beeps and report sent
to the system by User Code 254
Notice!
As the key-switch operates the arm/disarm successfully, the siren sounds short to indicate it.
16 - Delay Exit
The delay exit zone will perform as below:
1.
2.
3.
17 - Interior Delay Exit
The Interior delay exit zone will perform as below:
1.
2.
3.
2013.07 | 03 | F.01U.267.112
COM
Zone
COM
Zone
DISARM: Same as Instant zone disarm status
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Entry time starts - no Alarm / no report
Disarming during entry time - no Alarm / no report
Zone triggered - during exit time - no Alarm / no report / abbreviates remaining time
for exit to 5 s
Zone triggered - during entry time - no Alarm / no report
Zone triggered - entry time is expired - Alarm / report (report is delayed for 30sec,
when system is disarmed before, no report)
STAY ARM: Same as AWAY ARM performance.
First delay zone will start the entry time; all other delay zones will follow.
When System is disarmed and zone is not restored before, a Zone restore report is
sent.
Disarm: same as the Instant Zone disarm status
AWAY Arm: same as the Delay Exit Zone AWAY Arm status
STAY Arm:
This Zone will be Ignored and performed as disarm.
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitsysteme GmbH
EN