Occasionally abnormal
communication in use of
Contact ID/personal
telephone alarm.
No response from keypad and
alarm siren (disabled) when
an alarm is triggered by the
zone.
The control panel cannot
send any reports
(programmed to send reports
to receiver).
A-LINK cannot be connected
with ITS- DX4020-G.
Bosch Sicherheitsysteme GmbH
Extension system is used
in the telephone
network.
The telephone network
support ADSL as well.
The zone silent alarm is
enabled.
The transmission format
of the receiver is
programmed to 0 = not
used.
The parameters of ITS-
DX4020-G are not
properly set.
Installation Guide
Troubleshooting | en
Add dial delay in
programming.
Connect the system after
the ADSL filter.
Disable the zone silent
alarm.
Program the
transmission format of
the receiver to 1 or 3.
Recommend to set the
parameter ACK TIMEOUT
of ITS-DX4020-G to the
maximum (600) and set
TRANSMIT BUFFER LIFE
TIME to the maximum
(120).