Firmware Upgrade With The Icp-Ezru2 Upgrade Key - Bosch AMAX panel 4000 Installation Manual

Icp-amax4-p1 / icp-amax4-p2-en / icp-amax-p3-en
Hide thumbs Also See for AMAX panel 4000:
Table of Contents

Advertisement

106
en | Configuration
1.
2.
3.
LED/Icon LCD keypad can also be used to copy key parameters to the alarm control panel. For
more information refer to Command 963 .
8.8

Firmware Upgrade with the ICP-EZRU2 Upgrade Key

Use Firmware Upgrade Key (green) to upgrade Firmware of alarm control panel.
Procedure:
2013.07 | 03 | F.01U.267.112
Connect the programming key to the plug marked as "PROGRAMMING KEY" on the top of
the printed circuit board (PCB) of the alarm control panel. Please note that the direction
of the programming key should be consistent with the direction marked on the PCB.
Select text keypad installation menu [ADDRESS/KEY PROGR – COPY DATA TO PANEL]
and Press [#]. After successfully copying the programming data in programming key to
the alarm control panel, the confirmation tone will be sounded. Wrong prompt tone and
display of [Failure of Key Parameters to Control Panel] indicate damage of programming
key data. The data need to be copied into the alarm control panel again.
Unplug the programming key from the alarm control panel.
Power OFF alarm control panel. Also remove battery. Unplug USB cable, if plugged.
Locate the socket labeled PROGRAMMING KEY at the top of the printed circuit board
(PCB). Observe the triangular markings on the PCB and align them with the markings on
the upgrade key.
Power ON alarm control panel. Observe LED of upgrade key lights steady during upgrade
is sent to alarm control panel. This takes about one minute. When upgrade is terminated,
LED is blinking.
Remove upgrade key
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitsysteme GmbH
EN