Condition:
No communication with the DX4020/ITS-DX4020G if DX4020/ITS-DX4020G is programmed.
Restore:
Communication with DX4020/ITS-DX4020G is normal and fault is reset.
Supervise:
1.
2.
3.
Condition:
No communication with DX3010 if DX3010 is programmed.
Restore:
Communication with DX3010 is normal and fault is reset.
Supervise:
1.
2.
3.
Condition:
No communication with DX2010 if DX2010 is programmed.
Restore:
Communication with DX2010 is normal and fault is reset.
Supervise:
1.
2.
3.
Module 4010 Missing
Condition:
No communication with DX4010 if printer is enabled.
Restore:
Communication with DX4010 is normal and fault is reset.
Supervise:
1.
2.
Bosch Sicherheitsysteme GmbH
Network / IP Module 1 Failure
Report the DX4020/ITS-DX4020G fault to configured destination on address 124 when
the fault is detected.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Output Expansion Module Failure
Report the DX3010 fault to configured destination on address 140 when the fault is
detected.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Input Expansion Module Failure
Report the DX2010 fault to configured destination on address 140 when the fault is
detected.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Printer Failure
Report the DX4010 missing fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)