Remote PC Setting
Address 0162 - 0179
RPC IP No
RPC Port Number
Control Panel DHCP Update Time (hours)
RPC is the remote programming computer equipped with remote programming software.
Remote Access To Panel When Panel Is Armed
Address 0180
0 = Disable, 1 = Enable ; Default 1
Keypad Language
Address 0181
0 = Default, 1 = EN, 2 = DE, 3 = ES, 4 = FR, 5 = IT, 6 = PL,
7 = NL, 8 = SE
Tamper Reset For User
Address 0182
0 = Disable, 1 = Enable
Arm / Disarm For Installer
Address 0183
0 = Disable, 1 = Enable
Zone Tamper Bypass when DEOL Zone is Bypassed
Address 0184
0 = Disable, 1 = Enable
Call Back Setting
Address 0196
0 = Disable, 1 = Enable
Silence Warning Device When Disarmed
Address 0197
0 = Disable, 1 = Enable
Bosch Sicherheitsysteme GmbH
This function is only accessible in address programming
Installation Guide
Programming | en
Address
Default
0162 - 0173
15
0174 - 0178
15
0179
15
Address
Default
0180
1
Address
Default
0181
0
Address
Default
0182
1
Address
Default
0183
0
Address
Default
0184
1
0=Incert
Address
Default
0196
0
Address
Default
0197
1