Programming; Spe Blocking Element Function Test; Completing The System Installation - Bosch SE 60 LSNi Installation Manual

Smartkey blocking unit
Table of Contents

Advertisement

Installation instructions
4.

Programming

Programming of the SE 60 LSNi and all other system components is performed by the
corresponding program on the control panel.
5.

SPE blocking element function test

Turn on the power supply
Before turning on the power supply, make sure that bridge B1 is inserted in the control unit
Turn on the power
Functional test
1. Remove the jumper from B1 on the control unit and insert it in B3.
The SPE blocking element bolt extends. Yellow LED lights up on the control unit.
2. Remove the jumper from B3 on the control unit.
The SPE blocking element bolt retracts. The LED on the control unit goes out.
3. Repeat steps 1–2 with the door closed, to check the bolt on the SPE blocking element fits into
the bolt receiver accurately.
4. After the function test, insert the jumper back into bridge B1 in the control unit.
The yellow LED on the control unit circuit board shows the status of the system, as follows:
LED
Status
off
System is OK.
Single flashing
Bolt does not extend or
pulse
retract.
6.

Completing the system installation

After completing the connection work:
1. Make sure that bridge BR1 is closed in the control unit for normal operation.
2. Place the cover on the control unit.
3. Carry out a check of the system.
Required action
None
Check the SPE blocking element and the
bolt receiver are correctly mounted and
check the electrical connection
Repeat the test