Example With Incorrect Descriptions - Panasonic KX-UDS124 Administrator's Manual

Cell station unit (sip)
Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

3.5.2 Example with Incorrect Descriptions

# Enable G726-32K
CODEC_ENABLE2_1="Y"
CODEC_PRIORITY2_1="1"
# Enable G729A
CODEC_ENABLE3_1="Y"
CODEC_PRIORITY3_1="1"
# Disable PCMU
CODEC_ENABLE4_1="N"
Setting the G.729A Codec Only
## Codec Settings
# Disable G722
CODEC_ENABLE0_1="N"
# Disable PCMA
CODEC_ENABLE1_1="N"
# Disable G726-32K
CODEC_ENABLE2_1="N"
# Enable G729A
CODEC_ENABLE3_1="Y"
CODEC_PRIORITY3_1="1"
# Disable PCMU
CODEC_ENABLE4_1="N"
# Do not set PCMU
CODEC_G711_REQ="0"
3.5.2 Example with Incorrect Descriptions
The following listing shows an example of a configuration file that contains incorrect formatting:
An improper description is entered in the first line. A configuration file must start with the designated
character sequence "# Panasonic SIP Phone Standard Format File #".
Comment lines start in the middle of the lines.
Space characters are inserted in the middle of the setting line.
A specified value is not in the range allowed for that setting.
Incorrect Example
# This is a simplified sample configuration file.
############################################################
# Configuration Setting #
############################################################