The firmware update process of each SIP-CS
Step 1
The SIP-CS downloads a configuration file from the
provisioning server.
For details about setting the timing of when
configuration files are downloaded, see
3.2.4 Downloading Configuration Files.
Step 2
The SIP-CS compares the version number of the
firmware in the configuration file to the SIP-CS's
current firmware version.
(In this example, the SIP-CS is using version
01.000 and the configuration file specifies version
01.050.)
Step 3
When a newer firmware version is specified in the
configuration file, the SIP-CS will download the
firmware from the address specified under
"FIRM_FILE_PATH" in the configuration file.
Step 4
Once the newer firmware is downloaded, it is
applied to the SIP-CS and the SIP-CS automatically
restarts.
Step 5
The firmware updates for the S-PSs will be
executed.

7.5 Local Firmware Update

When an updated version of the firmware is provided on a Web site or other means, you can perform the
firmware update manually using Web user interface programming.
After the firmware is uploaded to the Super Master CS, the Super Master CS distributes the firmware to all
other SIP-CSs.
Document Version 2013-03
Provisioning Server Address
Configuration File
SIP-CS
Version
01.000
Current Version
SIP-CS
FIRM_VERSION="01.050"
http://firm.example.com/
firm/01.050.fw
01.050.fw
SIP-CS
Version
01.050
Version Updated
SIP-CS
7.5 Local Firmware Update
Provisioning
Server
Compare
Provisioned
Configuration File
Firmware
Server
Administrator Guide
269

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents