Sip_Timer_T4 - Panasonic KX-UDS124 Administrator's Manual

Cell station unit (sip)
Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

4.6.2 SIP Settings
Value Range
Default Value

SIP_TIMER_T4

Value Format
Description
Value Range
Default Value
SIP_FOVR_NORSP
Value Format
Description
Value Range
Default Value
SIP_FOVR_MAX
Value Format
Description
Value Range
Default Value
228
Administrator Guide
2
4
8
16
32
4
Integer
Specifies the maximum period, in seconds, that a message can remain
on the network.
0
1
2
3
4
5
0
Boolean
Specifies whether to perform the fail-over process when the SIP-CS
detects that the SIP server is not replying to SIP message.
Y (Enable fail-over)
N (Disable fail-over)
Note
If set to "Y", the SIP-CS will try to use the other SIP servers via
the DNS SRV and A records.
If set to "N", the SIP-CS will not try to use the other SIP servers.
Y
Integer
Specifies the maximum number of servers (including the first [normal]
server) used in the fail-over process.
1–4
2