Download Timing
At regular intervals of time
Document Version 2013-03
The configuration files are downloaded at specified intervals of time, set in
minutes. In the example below, the SIP-CS has been programmed to check
for and download configuration files from the provisioning server every 3
days (4320 minutes).
Power On
3 days later
6 days later
The configuration files are downloaded periodically under the following
conditions:
•
In the configuration file, add the line, CFG_CYCLIC="Y".
–
Set an interval (minutes) by specifying "CFG_CYCLIC_INTVL".
•
In the Web user interface:
–
Click the [Maintenance] tab, click [Provisioning Maintenance],
and then select [Yes] for [Cyclic Auto Resync].
–
Enter an interval (minutes) in [Resync Interval].
Note
•
The interval may be determined by your dealer. A maximum interval
of 28 days (40320 minutes) can be set on the SIP-CS.
3.2.4 Downloading Configuration Files
Explanation
CFG_CYCLIC_INTVL="4320"
SIP-CS
Check
Download
Check
Download
Check
Download
Provisioning
Server
Administrator Guide