11.2.3 Removing processor
Field Replaceable Unit
(FRU)
Tools: Tool-less
V
CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.2.3.1 Preliminary steps
"Disabling BitLocker functionality" on page 63
Ê
"Shutting down the server" on page 40
Ê
"Disconnecting the server from the mains" on page 41
Ê
"Getting access to the component" on page 42
Ê
"Removing the heat sink" on page 143
Ê
11.2.3.2 Removing a processor
I
This description applies to the following procedures:
– Removing processor from a defective system board (see section
"Replacing the system board" on page
Ê Remove the desired processor heat sink as described in section
the heat sink" on page
TX1310 M1
143.
Upgrade and Maintenance Manual
Hardware: 15 minutes
Software: 5 minutes
206)
Processor
"Removing
145