Series 3100/3500 Product Reference Guide
5.
Specify a range of NVM to transfer. Choose All or None.
6.
If the system has EMS installed, it prompts for the range to transfer (otherwise, the
program skips this screen):
The range is specified in page numbers (16 KB per page). Use <RightArrow> and
<LeftArrow> to move between the Start and End values. Use <UpArrow> and
<DownArrow> to change the page number value.
Set the range and press <Enter>.
7.
The terminal displays a range verification screen. For example:
If the values are correct, press <Enter>. If the values are not correct, press <Clear>
to clear the fields and select new values.
8.
Specify the baud rate. Use the <UpArrow> and <DownArrow> to scroll through
the list of baud rates until the correct rate is displayed, and press <Enter>. (Flow
control may be necessary at 38400 bps and higher.)
9.
Specify the data bits. Press <7> or <8>, or use <UpArrow> and <DownArrow> to
display 7 or 8, and press <Enter>.
Note:
If you select 8 data bits, the program selects No parity
and skips the next screen.
10. Specify parity type. Use <UpArrow> and <DownArrow> to display a parity
option, or press the first letter of a parity option (Even, Odd, None, Space, or Mark)
and press <Enter>.
11. Set flow control. Use <UpArrow> and <DownArrow> to display the flow control
options, or press the first letter of an option (None, Xon/Xoff, or RTS/CTS) and
press <Enter>.
5-16
EMS
Use arrow keys
Start
End
RAM 0000 3FFF
NVM C839 DFFF
EMS
None
Correct?