Table 5-2. Troubleshooting Spectrum24 Terminals (Continued)
Problem
Battery is dead
Terminal disassociated
from Access Point
Explanation/Action
Battery not replaced after receiving low battery message or
terminal left on for more than 24 hours.
Replace the battery.
Note: Terminal loses software when power is lost. To reload
software, cold boot terminal and enter NetID manually. Associate
with AP and reacquire boot files as described in Initiate Network
Connection.
Application does not respond to interactive operations.
Applications using internal batch mode continue to function until
required to transmit via radio, then fail to work. No message
displayed.
Error Recovery and Troubleshooting
5-7