Troubleshooting - Apollo VioNet 3000 series User Manual And Instruction Manual

Vionet 3000 series mobile router
Hide thumbs Also See for VioNet 3000 series:
Table of Contents

Advertisement

command, all packets received that are classified in a VLAN that the port is not a member of are
dropped. Contrariwise the packets reach the forwarding process.
7.
In the output, you can configure how the packet is sent through the port. If you use the TAG-
INSERTION command, the untagged packets are sent with the default tag associated to the packet
input port (VLAN where the packet was classified in the input). If you use the TAG-REMOVAL
command, the tagged packets are sent without their tags.
feature vlan
enable
vlan 101 ethernet0/0 port 1
vlan 101 ethernet0/0 port internal
tag-default ethernet0/0 port 1 101
tag-insertion ethernet0/0 port internal
tag-removal ethernet0/0 port 1
exit
8.7

Troubleshooting

8.7.1
Prior Verifications
These are the prior verifications for any type of incident.
8.7.1.1
Wiring
Check the wiring, ensuring that:
The cable is category 5 or higher.
The cable status is correct and the pins are correct. Pin to pin if you are connected to a HUB
or SWITCH, (1-1, 2-2, 3-3 and 6-6) or crossover if you are connected to a PC (1-3, 2-6, 3-1
and 6-2).
The hub/switch is connected to the desired device.
8.7.1.2
LED
The status indicators of the LEDs indicate the following:
LED:
Green On:
Green Off:
Orange Flashing:
Organge Off:
8.7.2
General Checks
8.7.2.1
Check the Status of an Interface
There are two ways to view the status of an interface. Check the general configuration or see what
state the interface is in. Execute the following commands:
+ configuration
Teldat's Router, ATLAS250 6 96
P.C.B.=74
Mask=0a01
KHz
.
.
6 interfaces:
Connector
Interface
FE0/LAN1
ethernet0/0
FE1/LAN2
ethernet0/1
.
.
SNMP OperStatus:
Interface
ethernet0/0
ethernet0/1
"Status" indicated the current status of the network,that can be in the following states:
Page 50
Status:
Physical layer established.
No physical layer.
There is packet traffic. Flashing is dependent upon the traffic quality.
No packet traffic
S/N: 472/06842
Microcode=134f0
MAC/Data-Link
Ethernet/IEEE 802.3
Ethernet/IEEE 802.3
OperStatus
Up
Down
Apollo Video Technology
th
Avenue Southeast – Bothell, WA 98021-8990
24000-35
Toll Free: 888-AVT-USA1; Tel: 425.483.7100; Fax: 425.483.7200
www.apollovideo.com
CLK=449664 KHz
BUSCLK=74944 KHz PCICLK=56208
Status
Up
Down

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vn-3001Vn-3011aVn-3011bVn-3021c

Table of Contents