Figure 17: Configuration Connection - Apollo VioNet 3000 series User Manual And Instruction Manual

Vionet 3000 series mobile router
Hide thumbs Also See for VioNet 3000 series:
Table of Contents

Advertisement

3.2.1.3.2
The VioNet Router includes a default configuration that activates if the device has not been
previously configured.
The router's default configuration establishes the following IP address and access mask:
NOTE: Some devices leave the factory with a customized configuration for a specific
client. This personalization can mean that the default configuration may be different from
the one shown above.
This initial configuration allows access to the device's configuration console through the Telnet IP
protocol:
Configure the Ethernet interface on the IP terminal (normally a PC) using the IP address from
the following range [192.168.1.50, 192.168.1.100] and mask 255.255.255.0. ie: 192.168.1.50,
255.255.255.0.
Connect the IP terminal's Ethernet interface to any of the Ethernet Switch ports on the Router
(the LAN1.4 connectors) through the Ethernet patch cable (RJ45) which is provided.
Start a Telnet session from the IP terminal to IP address 192.168.1.254 (the Router's default
address).
The default configuration will ask for login credentials (user/password) to access the console.
Page 14
- No parity bit
- No type of flow control
NOTE: Connection to the configuration port can be carried out using a DB9 Male
connector to a DB9 Female. In cases where the terminal has DB25 connectors, an
additional adapter is required.

Figure 17: Configuration Connection

Configuring through the IP terminal (LAN 1.4 Connectors)
IP Address: 192.168.1.254
IP Mask: 255.255.255.0
o
User: admin
o
Password: access
Apollo Video Technology
th
Avenue Southeast – Bothell, WA 98021-8990
24000-35
Toll Free: 888-AVT-USA1; Tel: 425.483.7100; Fax: 425.483.7200
www.apollovideo.com