Config - Comtech EF Data CDM-600 Installation And Operation Manual

Open network satellite modem (2.4 kbps – 20 mbps)
Hide thumbs Also See for CDM-600:
Table of Contents

Advertisement

CDM-600 Satellite Modem
Front Panel Operation
6.3.1

CONFIG

CONFIG:
EDMAC
The sub-branches available are:
ALL
MODE
TX
(Transmit)
RX
(Receive)
CLOCKS
D&I
EDMAC
MISC
REMOTE
(Remote Control)
MASK
IMPED
(Impedance)
STATS
(Statistics)
IMPORTANT
ALL
MODE
TX
MISC
REMOTE
Permits the user to completely configure the unit, being prompted, step
by step, to make choices, or edit data. This is highly recommended for
new users, as it will clearly lead the user through all the configuration
parameters.
Permits the user to select Frame Type and Data Format for TX and RX.
Permits the user to define, on a parameter-by-parameter basis, the TX
configuration of the unit. These menu sub-branches would be used if the
user wished to change, for example, just the TX Frequency.
Permits the user to define, on a parameter-by-parameter basis, the RX
configuration of the unit. These menu sub-branches would be used if the
user wished to change, for example, just the RX data rate.
Permits the user to select TX-Clocking, RX-Buffer/Clock, or External
Reference.
Permits the user to select Drop or Insert options.
Permits the user to select EDMAC options.
Permits the user to select, view, or change various other parameters.
Permits the user to define whether the unit is being controlled locally, or
remotely, and to configure the Remote Control parameters: baud rate,
I/O format, address.
Permits the user to activate or MASK an alarm condition.
Permits the user to select the impedance at the IF connectors,
either 50 or 75 Ω.
Permits the user to enable and configure the logging of various statistics,
including Eb/No and AUPC parameters
The modem may be monitored over the remote control bus at any
time. When in Local mode, however, configuration parameters may
only be changed through the front panel. Conversely, when in
Remote mode, the unit may be monitored from the front panel, but
configuration parameters may only be changed via the remote
control bus.
6–6
RX
CLOCKS
MASK
IMPED
STATS
Revision 7
MN/CDM600.IOM
D&I

Advertisement

Table of Contents
loading

Table of Contents