CDM-600 Satellite Modem
Front Panel Operation
If the Warm-up Delay is enabled, when the modem is powered up, a Warm-Up Delay
Countdown will be activated, during which the TX is suppressed. The Countdown of the
remaining Warm-up Delay is displayed on the front panel, for example:
COMTECH CDM-600
HIGH-STABILITY REF WARMING UP: 045 SEC
If necessary, this Warm-up period can be by-passed by pressing the CLEAR key.
6.3.1.9

CONFIG: REMOTE CONTROL

REMOTE CONTROL = LOCAL
Select LOCAL or REMOTE using the [↑] [↓] arrow keys, then press ENTER.
If LOCAL is selected, the REMOTE CONTROL is disabled. Remote monitoring is
still possible.
If REMOTE is selected, then the following sub-menus will be displayed.
ONFIG: REMOTE CONTROL: INTERFACE
INTERFACE= RS-485-4W
Use the [←] [→] arrow keys to select the parameter to edit: Interface, Address or
Baudrate.
Edit the Interface type, Baudrate and each digit of the Address using the [↑] [↓] arrow
keys.
ADDRESS= 0001
For EIA-485, the permitted address range is 1 to 9999.
Address 0 is reserved for universal addressing.
For EIA-232, the Address is fixed at 0000.
OPEN NETWORK MODEM
(LOCAL,REMOTE)
(232,485-2,485-4)
BAUDRATE= 9600
6–26
Revision 7
MN/CDM600.IOM