CDM-600 Satellite Modem
Remote Control
Command
Arguments
Parameter
(Instruction
for Command
Code and
or Response
Type
to Query
Qualifier)
Tx Carrier
TXO=
1 byte, value
State
of 0 thru 3
AUPC Enable
AUP=
1 byte, 0 or 1
AUPC
APP=
6 bytes
Parameters
Description of Arguments
Command or Query.
Tx Carrier State, where:
0=OFF due to front panel or remote control command
1=ON
2=RTI (receive/transmit inhibit)
3=OFF due to ext H/W Tx Carrier Off command (not a
valid argument when used as a command, and not
indicated in MGC? response)
Example: TXO=1 (Tx Carrier ON)
Command or Query.
AUPC mode enable/disable, where:
0=Disabled
1=Enabled
Example: AUP=1
Note: EDMAC or D&I++ or ESC++ framing must be
selected for the AUPC feature to be available.
Command or Query.
Defines AUPC operating parameters. Has the form
abc.cd, where:
a=Defines action on max. power condition.
(0=do nothing, 1=generate Tx alarm)
b=Defines action on remote demod unlock.
(0=go to nominal power, 1=go to max power)
c.c=target Eb/No value, for remote demod, from 0.0 to
9.9 dB
d =Max increase in Tx Power permitted, from
0.0 to 9.0 dB
Example: APP=015.67 (Sets no alarm, max power, 5.6 dB
target and 7 dB power increase.
16–11
MN/CDM600.IOM
Query
Response
(Instruction
to
Response to Query
Code and
Command
Qualifier)
TXO=
TXO?
TXO=x
TXO?
(see description of
arguments)
TXO*
TXO#
AUP=
AUP?
AUP=x
AUP?
(see description of
arguments)
AUP*
AUP#
APP=
APP?
APP=abc.cd
APP?
(see description of
arguments)
APP*
APP#