App=,; Tfm=, - Comtech EF Data CDM-600 Installation And Operation Manual

Open network satellite modem (2.4 kbps – 20 mbps)
Hide thumbs Also See for CDM-600:
Table of Contents

Advertisement

CDM-600 Satellite Modem
Remote Control
Command
Arguments for
Parameter
(Instruction
Command or
Code and
Response to
Type
Query
Qualifier)
Global
MGC=
118 bytes,
Configuration
with
numerical
entries, fixed
values and
delimiters
Description of Arguments
Command or Query.Global Configuration of
FFF.FFFFDDDDD.DDDGYRMVSPP.PBaaa.aa
CDM600, in the form:
CXIKNZfff.ffffddddd.dddgyrmvswwctt.tbbbb
biknzOEEEETAAAAAAWeLQUHHHHhhhhJJ
JJjjjjKkpqux, where:
same as TFQ
FFF.FFFF=Tx Frequency
same as TDR
DDDDD.DDD=TX Data Rate
same as TFT
G=Tx FEC Type
same as TRS
Y=Tx Reed-Solomon Type
same as TCR
R=Tx FEC Rate
same as TMD
M=Tx Modulation Type
same as TSI
V=Tx Spectrum Inversion
same as TSC
S=Tx Scrambler State
same as TPL
PP.P Tx Power Level
same as AUP
B=AUPC Enable
same as APP
aaa.aa=AUPC Parameter Setup
same as TCK
C=Tx Clock Source
same as TXO
X=Tx Carrier State
same as TIT
I=Tx Interface Type
same as TTC
K=Tx Ternary Code
same as TFM
N=Tx Framing Mode
same as TIP
Z=Tx IF Impedance
same as RFQ
fff.ffff=Rx Frequency
same as RDR
ddddd.ddd=Rx Data Rate
same as RFT
g=Rx FEC Type
same as RRS
y=Rx Reed-Solomon Type
same as RCR
r=Rx FEC Rate
same as RMD
m=Rx Modulation Type
same as RSI
v=Rx Spectrum Inversion
same as RDS
s=Rx Scrambler State
same as RSW
ww=Rx Sweep Width
same as RCK
c=Rx Clock Source
same as same as EBA
tt.t=Eb/No Alarm Point
same as RBS
bbbbb=Rx Buffer Size
same as RIT
i=Rx Interface Type
same as RTC
k=Rx Ternary Code
same as RFM
n=Rx Framing Mode
same as RIP
z=Rx IF Impedance
same as EFM (or ESC, when in IBS mode)
O=EDMAC or ESC Mode
same as ESA (or SCP, in IBS mode-xy00)
EEEE=EDMAC Address or ESC Para
same as TST (read only)
T=Unit Test Mode
same as MSK
AAAAAA=Unit Alarm Mask
same as EFR
W=Hi-Stab module: REF Setting
same as SSI
e=Statistics Sampling Interval
same as RTE
L=Rx Terrestrial Alarm Enable
same as TTA
Q=Tx Terrestrial Alarm Enable
same as ODU
U=ODU Common Enable
same as TBA
HHHH= Tx Backward Alarm
same as RBA
hhhh= Rx Backward Alarm
same as TVL
JJJJ=Tx Audio Volume
same as RVL
jjjj= Rx Audio Volume
same as DTY, ITY
k=Drop Type, k=Insert Type
same as TET, RET
p=Tx ESC Type, q=Rx ESC Type
same as ITD
u=Invert Tx Data
same as IRD
x= Invert Rx Data
16–26
MN/CDM600.IOM
Query
Response
(Instruction
to
Response to Query
Code and
Command
Qualifier)
MGC=
MGC?
MGC=FFF.FFFFDDD
DD.DDDGYRMVSPP.
MGC?
PBaaa.aaCXIKNZfff.f
MGC*
fffddddd.dddgyrmvs
MGC#
wwctt.tbbbbbiknzOE
EEETAAAAAAWeLQ
UHHHHhhhhJJJJjjjj
Kkpqux
(see description of
arguments)
Returns current
configuration
MGC?n
Where n = 0 to 9.
Returns the MGC
portion of 1 of 10
stored
configurations
Revision 7

Advertisement

Table of Contents
loading

Table of Contents