Cae=, - Comtech EF Data CDM-600 Installation And Operation Manual

Open network satellite modem (2.4 kbps – 20 mbps)
Hide thumbs Also See for CDM-600:
Table of Contents

Advertisement

CDM-600 Satellite Modem
Remote Control
Command
Arguments for
Parameter
(Instruction
Command or
Code and
Response to
Type
Query
Qualifier)
Retrieve next
N/A
80 bytes
5 unread
Stored
Events
Clear All
CAE=
None
Stored
Events
Description of Arguments
Query only.
Unit returns the oldest 5 Stored Events which have not
yet been read over the remote control.
Reply format: [CR]sub-body[CR]sub-body[CR]sub-
body[CR]sub-body[CR]sub-body, where Sub-
body=ABCddmmyyhhmmss,
A is the fault/clear indicator:
F=Fault
C=Clear
I=Info
B is the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Power on/off, or log cleared
5=Open Network
C is Fault Code number, as in FLT?
or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
ddmmyyhhmmss = date/time stamp.
If there are less than 5 events to be retrieved, the
remaining positions are padded with zeros.
If there are no new events, the response is RNE*.
Command only.
Forces the software to clear the software events log.
Example: CAE=
Note: This command takes no arguments
16–30
MN/CDM600.IOM
Query
Response
(Instruction
to
Response to Query
Code and
Command
Qualifier)
N/A
RNE?
RNE=[CR]ABCddmm
yyhhmmss[CR]ABC
ddmmyyhhmmss[CR
]ABCddmmyyhhmm
ss[CR]ABCddmmyy
hhmmss[CR]ABCdd
mmyyhhmmss
(see description for
details of
arguments)
CAE=
N/A
N/A
CAE?
CAE*
CAE#
Revision 7