Electrical Safety - Comtech EF Data CDM-600 Installation And Operation Manual

Open network satellite modem (2.4 kbps – 20 mbps)
Hide thumbs Also See for CDM-600:
Table of Contents

Advertisement

CDM-600 Satellite Modem
Preface

Electrical Safety

The CDM-600 Modem has been shown to comply with the following safety standard:
The equipment is rated for operation over the range 100 - 240 volts AC. It has a
maximum power consumption of 40 watts, and draws a maximum of 400 mA.
IMPORTANT
Fuses
The CDM-600 is fitted with two fuses - one each for line and neutral connections. These
are contained within the body of the IEC power inlet connector, behind a small plastic
flap.
For 230 volt AC operation, use T0.75A, 20mm fuses.
For 115 volt AC operation, use T1.25A fuses, 20mm fuses.
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES
WITH THE CORRECT TYPE AND RATING.
Environmental
The CDM-600 must not be operated in an environment where the unit is exposed to
extremes of temperature outside the ambient range 0 to 50°C, precipitation, condensation,
or humid atmospheres above 95% RH, altitudes (un-pressurised) greater than 2000
metres, excessive dust or vibration, flammable gases, corrosive or explosive atmospheres.
Operation in vehicles or other transportable installations that are equipped to provide a
stable environment is permitted. If such vehicles do not provide a stable environment,
safety of the equipment to EN60950 may not be guaranteed.
EN 60950: Safety of Information Technology Equipment, including
electrical business machines.
The user should observe the following instructions:
xiii
Revision 7
MN/CDM600.IOM

Advertisement

Table of Contents
loading

Table of Contents