(2) Detaching and refitting the fixing unit thermistor
Follow the procedure below to replace the fixing unit thermistor.
Procedure
1. Remove the fixing unit (see page 1-6-48).
2. Remove the screw and detach the connector,
and then remove the fixing unit thermistor.
3. Replace the fixing unit thermistor and refit all
the removed parts.
(3) Detaching and refitting the heat roller separation claws
Follow the procedure below to replace the heat roller separation claws.
Procedure
1. Remove the fixing unit (see page 1-6-48).
2. Remove the spring from each of the five heat
roller separation claws and then the claws.
3. Replace the heat roller separation claws and
refit all the removed parts.
Connector
Figure 1-6-70
Heat roller separation claws
Figure 1-6-71
2AV/X
Fixing unit thermister
Springs
1-6-49