Installing The Key Counter (Option) - Kyocera Mita KM-1530 Service Manual

Kyocera mita copier service manual
Hide thumbs Also See for KM-1530:
Table of Contents

Advertisement

2AV/X

1-3-4 Installing the key counter (option)

Key counter installation requires the following parts:
Key counter set (P/N 2A369702)
Contents of the set:
• Key counter cover (P/N 2A360010)
• Key counter retainer (P/N 66060030)
• Key counter cover retainer (P/N 66060022)
• Key counter mount (P/N 66060040)
• Key counter socket assembly (P/N 41529210)
• One (1) M3 × 8 bronze binding screw (P/N B1303080)
• Four (4) M4 × 6 bronze TP-A screws (P/N B4304060)
• Two (2) M4 × 10 bronze TP-A screws (P/N B4304100)
• One (1) M4 × 20 bronze TP-A screws (P/N B4304200)
1-3
• One (1) M4 × 6 chrome TP-A screw (P/N B4104060)
• Two (2) M3 × 6 bronze flat-head screws (P/N B2303060)
• One (1) M3 bronze nut (P/N C2303000)
Procedure
1. Fit the key counter socket assembly to the key
counter retainer using the two screws and nut.
2. Fit the key counter mount to the key counter
cover using the two screws, and attach the key
counter retainer to the mount using the two
screws.
3. Open the front cover.
4. Remove the screw on the front of the internal
eject tray.
5. Remove the five screws. While lifting the
internal eject tray, remove the right cover.
6. Cut out the aperture plate on the right cover
using a pair of nippers.
7. Pass the 4-pin connector inside the copier
through the aperture.
1-3-22
M4 × 6 screws
(B4304060)
Key counter retainer (66060030)
M3 nut
(C2303000)
M4 × 6 screws
(B4304060)
Key counter socket
assembly (41529210)
M3 × 6 flat-head screws (B2303060)
Figure 1-3-19
Screw
Front cover
Internal eject tray
Figure 1-3-20
Key counter mount (66060040)
Key counter cover
(2A360010)
Screws
Right cover
Screws
Aperture
4-pin connector
plate

Hide quick links: