2AV/X
(12) Adjusting the margins for scanning an original on the contact glass
Perform the following adjustment if the margins are not correct.
U402
(P. 1-6-15)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
• 20 cpm
Enter "403" using the numeric keys.
Select the item to be adjusted using
1-6
Yes
1-6-38
U404
U403
(P. 1-4-46)
Start
Enter maintenance mode.
Press the start key.
the cursor up/down keys.
Press the interrupt key.
Press the start key
to make a test copy.
Are the margins correct?
Yes
Proceed to another mode?
No
Press the stop/clear key to
exit maintenance mode.
End
A MGN: scanner left margin
B MGN: scanner leading edge margin
C MGN: scanner right margin
D MGN: scanner trailing edge margin
Press the start key.
The new setting
is stored.
Change the setting.
Increasing the value using the cursor
No
right key makes the margin wider.
Decreasing the value using the
cursor left key makes the margin
narrower.
Setting range (default)
Scanner left margin: 0 – +10 (2)
Scanner leading edge margin: 0 – +10 (3)
Scanner right margin: 0 – +10 (2)
Scanner trailing edge margin: 0 – +10 (2)
Changing the value by one moves
the margin by 0.5 mm for all.
Scanner leading edge margin
Ejection direction
(reference)
left margin
(2
(3 ± 2.5 mm)
Scanner
+2.0
mm)
–1.5
Scanner trailing edge margin
+2.0
(2
mm)
–1.5
Scanner
right margin
+2.0
(2
mm)
–1.5