Detaching And Refitting The Drum Separation Claw Assemblies; Detaching And Refitting The Cleaning Lower Seal Assembly - Kyocera Mita KM-1530 Service Manual

Kyocera mita copier service manual
Hide thumbs Also See for KM-1530:
Table of Contents

Advertisement

(2) Detaching and refitting the drum separation claw assemblies

Follow the procedure to replace the drum separation claw assemblies.
Procedure
1. Remove the image formation unit (see page
1-6-40).
2. Remove the screw holding each of the drum
separation claw assemblies and then the
assemblies.
3. Remove the drum separation claws from the
drum separation claw assemblies.
4. Replace the drum separation claws and refit
all the removed parts.

(3) Detaching and refitting the cleaning lower seal assembly

Follow the procedure below to replace the cleaning lower seal assembly.
Procedure
1. Remove the image formation unit (see page
1-6-40).
2. Remove the drum (see page 1-6-43).
3. Remove the two screws holding the cleaning
lower seal assembly and then the assembly.
Caution: When detaching and refitting the
cleaning lower seal assembly, take care not
to lose the M3 retainers (P/N 3330208).
4. Replace the cleaning lower seal assembly
and refit all the removed parts.
Drum separation claw assemblies
Figure 1-6-66
M3 retainers
Cleaning lower seal assembly
Figure 1-6-67
2AV/X
1-6
1-6-47