Installing The Original Size Detection Sensor (Option For The Metric Specifications Of The 15 Cpm Copier Only) - Kyocera Mita KM-1530 Service Manual

Kyocera mita copier service manual
Hide thumbs Also See for KM-1530:
Table of Contents

Advertisement

2AV/X
1-3-5 Installing the original size detection sensor (option for the metric specifications of
the 15 cpm copier only)
Original size detection sensor installation requires the following parts:
• Original size detection sensor (P/N 35927290)
• One (1) M3 × 8 bronze binding screw (P/N B1303080)
Procedure
1. Remove the original cover or the DF.
2. Remove the five screws holding the right
cover. While shifting the right cover in the di-
rection of the arrow in the diagram, remove the
contact glass.
1-3
3. Remove the eight screws holding the ISU
cover and then the cover.
4. Fit the original size detection sensor using the
screw.
5. Connect the 3-pin connector that was contain-
ed inside the ISU cover to the original size
detection sensor.
6. Refit all the removed parts.
7. Turn the main switch on and enter mainte-
nance mode.
8. Run maintenance item U075 and select "On".
9. Exit maintenance mode.
10. Check that the automatic original size detec-
tion is performed correctly.
1-3-24
Contact glass
Figure 1-3-22
ISU cover
Figure 1-3-23
M3 × 8 screw (B1303080)
Original size
detection sensor
3-pin connector
Figure 1-3-24