2AV/X
(10) Adjusting the scanner leading edge registration
Perform the following adjustment if there is regular error between the leading edges of the copy image and original.
U034
(P. 1-6-10)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Enter "066" using the numeric keys.
the start key to make a test copy.
1-6
1-6-36
U071
U066
(P. 1-4-14)
Start
Enter maintenance mode.
Press the start key.
Press the interrupt key.
Place an original and press
Is the scanner
leading edge registration
correct?
Yes
Press the stop/clear key to
exit maintenance mode.
End
Scanner leading edge registration
Original
Press the start key.
The new setting
is stored.
• 20 cpm
For copy example 1, increase
the value using the cursor right key.
For copy example 2, decrease
No
the value using the cursor left key.
• 15 cpm
For copy example 1, increase
the value using the zoom (+) key.
For copy example 2, decrease
the value using the zoom (–) key.
Setting range : –15 – +15 (20 cpm)
: –32 – +32 (15 cpm)
Initial setting: 0
Changing the value by 1 moves
the leading edge by 0.17 mm.
Copy
Copy
example 2
example 1
Figure 1-6-51