GENLOCK
ON: Select this mode when you gen-lock the unit
through an external device (such as a recorder).
Images via the EXT IN connector are not displayed
on Monitor 1 to 4.
OFF: Select this mode when you don't gen-lock the unit
through an external device. Images via the EXT IN
connector can be displayed on Monitor 1 to 4.
The factory default setting is GENLOCK OFF.
Notes:
• If GENLOCK ON is selected, the playback images or
multiscreen display cannot be displayed on Monitor 1
to 4. Confirm the images on the monitor which are con-
nected to the recorder.
• If GENLOCK OFF is selected, the maximum rate
recording becomes unavailable (when WJ-HD500A is
connected to the unit).
• CAMERA CLEANING
ON: Activates the manual cleaning for the cameras.
OFF: Deactivates the manual cleaning.
When you set CAMERA CLEANING to ON and exit from the
SETUP MENU, camera cleaning will start.
The factory default setting is OFF.
Notes:
• When the camera cleaning is active, cleaning will begin
from CAM 1 in numerical order.
• Surveillance is impossible during the cleaning.
• The cleaning cannot be stopped after it is started.
• Refer to pp. 34 and 36 for details on RS-485 or PS·Data
connections.
• The camera address needs to be corresponding with
the camera number.

OPERATOR REGISTRATION

700 OPERATOR REGISTRATION
OPERATOR NO.= 1
ID
PASSWORD=*****
PRIORITY=1
LEVEL
CAM01=VIEW&CONTROL CAM09=VIEW&CONTROL
CAM02=VIEW&CONTROL CAM10=VIEW&CONTROL
CAM03=VIEW&CONTROL CAM11=VIEW&CONTROL
CAM04=VIEW&CONTROL CAM12=VIEW&CONTROL
CAM05=VIEW&CONTROL CAM13=VIEW&CONTROL
CAM06=VIEW&CONTROL CAM14=VIEW&CONTROL
CAM07=VIEW&CONTROL CAM15=VIEW&CONTROL
CAM08=VIEW&CONTROL CAM16=VIEW&CONTROL
How to Display
To display this menu on the monitor, move the cursor to
700 OPERATOR REGISTRATION in SETUP MENU by mov-
ing the joystick to
.Then, press the CAM (SET) button. The
50
=150
=1
submenu appears on the monitor.
Parameters
Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para-
meters.
Press the numeric button(s) to enter a number.
• OPERATOR NO.
This stands for an operator number. When you enter the
number by pressing the NEXT, PREV or numeric button(s),
this menu will display the associated operator's information.
1 to 16 is available.
• ID
This stands for an operator ID. 1 to 99999 is available.
• PASSWORD
This stands for an operator's password. 1 to 99999 is avail-
able. The password will be displayed as "*" on the monitor.
• PRIORITY
This stands for an operator's priority. 1 to 16 is available.
(Refer to p. 15 for details on Priority Lock.)
• LEVEL
This stands for an operator's restrict level. It is configurable
through Level Table (refer to p. 60
Console what kind of restriction is given to the operator. 1
to 3 is available.
• CAM 01 to 16:
These stand for an operator's camera operation coverage.
The following are the parameters.
VIEW & CONTROL: The operator can display the
camera image on the monitor and control pan-
ning/tilting.
VIEW ONLY: The operator can display the camera
image on the monitor, but cannot control the
panning/tilting.
PROHIBITED: The operator can neither display the
camera image on the monitor nor control the
panning/tilting.
The following is the factory default setting of this menu.
OPERATOR NO.
ID
PASSWORD
1
150
2
1
3
100
4
101
5
102
6
103
CAM 1 to 16 = VIEW & CONTROL (for OPERATOR NO. 1 to
6
Note: When you enter an invalid number, the parameter will
return to the state before your numerical entry.
) of SX150 Admin
LEVEL
PRIORITY
150
1
1
12345
1
2
100
1
3
101
1
4
102
2
5
103
3
6