ALARM CONTROL

Alarm Mode

When alarm (sensor) is accepted, the matrix switcher's
operation mode changes into the alarm mode. Then, the
system operates as follows:
• The camera image (alarm image) appears on the moni-
tor 1.
The alarm inputs 1 to 6 are associated with the camera
input connectors 1 to 16.
For example, when the alarm (sensor) connected to the
alarm input 1 becomes active, Camera 1's image
appears on the Unit n (n is a monitor's unit address
number).
• "ALARMnn" appears on the monitor.
The display indicates that the image is input through
the alarm nn (nn is the alarm number).
When more than one alarm input signal has been
accepted, "ALARMnn
The monitor and alarm number will appear on the LED
display. At the same time, the alarm indicator will blink,
the monitor indicator will light up, and the camera indi-
cator will go off.
* Even when more than one alarm signal has been input,
the matrix switcher system continues to display the
image of the first alarm input.
The display will continue until the first alarm input is
reset.
Notes:
• Alarm input will be automatically reset in 30 seconds.
The auto-recovery time is configurable through SETUP
MENU or SX150 Admin Console.
• Alarm events are configurable through SX150 SETUP
MENU or SX150 Admin Console. (Refer to p. 47 ALARM
EVENT or p. 58 Alarm Event.)

Operation during an Alarm Mode

While an alarm mode is active, you can do the following:
• Resetting all the alarm inputs (ALL RESET)
• Suspending all the alarm inputs (ALM SUSPENDED)
94
" appears on the monitor.
*

Resetting All the Alarm Inputs

You can reset all the alarm input signals at a time.
1. Select a monitor which displays "ALARM".
(Refer to the figure on p. 86.)
2. Press the SHIFT button, and then press the ALL RESET
button.
All the alarms will be reset.
Then, the LED display and indicators will return to the
state before the alarm input.
Note: You cannot reset the alarm input signals one by one.

Suspending All the Alarm Inputs

Use this function when you do not want to be disturbed by
an alarm input, for example, during the setup procedures.
1. To suspend all the alarm input signals, press the SHIFT
button., and then press the SUSPEND button.
The indicator beside the button will light up and "ALM
SUSPENDED" will appear on the monitor.
(Refer to the figure on p. 87.)
2. To cancel alarm suspension, do Step 1 again.
Notes:
• The alarm suspension is applied to all system units,
not to a selected one.
• An alarm which was input before the suspension
will continue to operate.