Operator Settings
If you control this unit with a terminal-mode system con-
troller, your operator information, controllable monitors and
auto log-in/log-out will be registrable and configurable.
• Operator registration: Up to 16 operators are available.
ID and password for operator identification are config-
urable. Level and priority can be assigned to each
operator. Each camera's control coverage is also con-
figurable.
• Level table: Restriction level for each password is cus-
tomizable.
• Monitor select (Monitor selection): Controllable monitor
can be assigned to each controller.
• Auto login/logout (Auto log-in/log-out): Auto log-in/log-
out is configurable for each controller.
Notes:
• These settings (except Operator registration) are con-
figurable only through SX150 Admin Console. Operator
registration is configurable through SETUP MENU and
SX150 Admin Console.
• When you control the unit with a PS·Data system con-
troller, the above settings will be invalid. Refer to the
system controller's operating instructions.
System Settings
SETUP MENU can configure the clock (time and date),
cable compensation and camera title.
Besides these settings, SX150 Admin Console can select
the data ports' baud rates.
• Clock (Time and date): The unit's time and date are
configurable.
• Cable compensation: Cable compensation type is
selectable depending on the distance between a cam-
era and the unit. It is also possible to determine whether
to send the VD2 timing pulse or control data with the
camera output signals.
• EXT IN: External synchronization of the EXT IN connec-
tor is set to ON or OFF.
• Camera title: Camera title is configurable to identify the
camera images on the monitor. SX150 Admin Console
can configure the camera title including original charac-
ters.
• Data port: Usually, the ports DATA 1 to 3 connect to the
terminal-mode system controllers. RS-485 cameras will
be connectable with the data port configurations
through SX150 Admin Console and SETUP MENU.
When you use the system controllers via the PS·Data
protocol, you need to configure the DATA 4 port setting
through SX150 Admin Console or SETUP MENU.
Setup File Operation
SX150 Admin Console can send a configuration file from
the PC to this unit. The utility can also send the file from the
unit to the PC for configuration.
• Put to a file: A configuration data is sent from the PC to
the unit.
43
• Get from a file: A configuration data is sent from the unit
to the PC.
• Select setup data file: A configuration data is selected
when sending it from the PC to the unit (or from the unit
to the PC.)
Note: These settings are configurable only through SX150
Admin Console.
SX150 Admin Console Configuration
The PC-related settings are configurable.
• Account Manager: SX150 Admin Console operators are
registrable and changeable.
• Communication (Serial) port: PC's usable communica-
tion port number and its baud rate (communication
speed) are configurable.