Data Port - Panasonic WJ-SX150 Operating Instructions Manual

Matrix switcher
Hide thumbs Also See for WJ-SX150:
Table of Contents

Advertisement

Note: The new character has not been saved in the
configuration data at this point. After closing the
Edit Font window, be sure to return to the Camera
Title window and click on the
ton.
• To Copy a Character
1. Click on the desired character in the User Font box.
2. Click on the Copy button.
3. Click on the blank in the User Font box to copy the
character.
4. Click the Paste button.
• To Delete a Character
1. Click on the desired character in the User Font box.
2. Click on the Delete button.
3. Click on the Save –> button.
65

Data Port

This window configures the parameters of each data port
(RS485, DATA 1 to 4 and DATA HDR port): the protocol, the
(Save Exit) but-
baud rate (communication speed), and the connected
cameras.
How to Display
To display this window, click on the
in the main window (p. 52).
Parameters
• RS-485 Port Group
Protocol: Select RS485 when an RS-485 camera is
Baud Rate: Select the desired baud rate (communica-
RS485 Camera Daisy (RS-485 Camera Daisy): Select
PS·Data mode: This stands for the PS·Data parameters
connected to the data port.
Select CU360C when the system controller is con-
nected to the data port.
Select PSD when the system controller is connected
to the DATA 4 port via the PS·Data protocol.
PS·Data mode will appear in the window.
tion speed). 4800, 9600 or 19200 bps is selectable.
the number(s) of the camera(s) connected to the
RS-485 daisy chain.
Data 1 to 3 are connectable to either of cameras
and system controllers.
When connecting cameras to these ports, select the
connected camera number(s).
of the DATA 4 port.
Logout Time: Select the desired operable time
before logout. OFF,10, 20, 30, 60, 90 or 120 sec
is available.
The factory default setting is 30 sec.
Alarm Data: Select the desired time to accept an
alarm input signal. OFF, 0, 1 or 5 sec is avail-
able.
The factory default setting is 1 sec.
Wait Time: Select the desired wait time to transmit
an alarm output signal. OFF, 100msec, 200m
(Data Port) button