3.4 Installation and Start-up

To prepare for powering on the cluster, see the component documentation for your model of
DLxxx-series server, HP ProCurve switch, and optional cluster components. Ensure that:
All component power switches are set to the off position.
You know the pattern of signal LEDs indicating that a component has powered up
successfully.
Use the following procedure to power up the cluster:
Caution:
Follow all electrical safety procedures mandated in the HP Cluster Platform Site Preparation Guide,
the HP BladeSystem Site Preparation Guide, and any procedures specific to your computer room
and your locale.
CPE BladeSystem with c7000 enclosure configurations are shipped cabled and with all of the
components mounted in the rack. Check all of the cable connections before applying power to
the CPE configuration. If any cables became loose during shipment, see the
reconnect them.
Warning!
Failure to adhere to the cable connections provided in
performance, or even damage to the system.
1.
Ensure that all of the breakers are set in the off position.
2.
Connect the main power inlet cable (callout 3 in
3.
Apply power to each PDU in turn.
4.
Apply power to each individual breaker bar (callout 7 in
5.
Apply power to each component in turn.
Each CPE BladeSystem with c7000 enclosure is factory tested prior to shipment to your site.
Operating system software is installed at the factory. All that is typically necessary is to connect
the power cable to the local power source and connect to your local area network (LAN). For
more information on setting up the enclosure, see the HP BladeSystem c7000 Enclosure Quick Setup
Instructions:
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00698534/c00698534.pdf
For more information on powering on the cluster, see the HP BladeSystem c7000 Enclosure Setup
and Installation Guide:
http://bizsupport.austin.hp.com/bc/docs/support/SupportManual/c00698286/c00698286.pdf
For information on the Onboard Administrator, see the HP BladeSystem Onboard Administrator
User Guide:
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00705292/c00705292.pdf
HP recommends that you read the HP BladeSystem c–Class Enclosure User Guide before reading
the HP BladeSystem Onboard Administrator User Guide. Reading these guides in order ensures that
you will obtain an overall understanding of the HP BladeSystem Onboard Administrator and
that you properly complete the initial setup to facilitate proper functioning of the Onboard
Administrator.
For information on the Onboard Administrator command line interface, see the HP BladeSystem
Onboard Administrator Command Line Interface User Guide:
50
CPE BladeSystem with c7000 Enclosure Configurations
Appendix D
can result in poor network
Figure
1-1) to the site power supply.
Figure
1-1).
Appendix D
to

Advertisement

Table of Contents
loading

Table of Contents