Typical 22U Cpe With Rack-Mountable Servers Configuration - HP Cluster Platform Express v2010 Overview

Workgroup system and cluster platform express overview and hardware installation guide
Hide thumbs Also See for Cluster Platform Express v2010:
Table of Contents

Advertisement

Figure 4-2 Typical 22U CPE with Rack-Mountable Servers Configuration
1
PCI-X
iLO
2
1
SCSI Port 1
UID
1
3
Mouse
Serial A
2
4
Video
Keybd
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
1
2
UID
PORT 13
PORT 14
PORT 15
PORT 16
PORT 17
PORT 18
PORT 19
PORT 20
PORT 21
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
PORT 9
Figure 4-2
shows the following cluster components:
1.
Rack rear view.
2.
Rack front view.
3.
Blank filler panels fill any unused slots, and are important for maintaining cooling airflow
within the rack.
Caution:
Do not remove filler panels or replace them with additional components. Doing so might
change the thermal characteristics of the rack and cause overheating and data loss.
4.
A ProLiant DL3xx-series server, functioning as the cluster's control node.
5.
The front view shows the keyboard, video, and mouse (KVM), used locally for cluster
administration operations such as software installation, or when a remote network connection
is not available. An optional 8-port KVM switch lets you connect the KVM to one or more
nodes. This switch is installed at the rear of the rack, behind the KVM with its ports facing
to the front (not as shown in
the component ports.)
6.
A 24-port HP ProCurve Ethernet switch, providing the cluster's administrative and console
management networks. In Gigabit Ethernet clusters, such switches also provide the
high-speed message-passing interface (MPI) network.
7.
Several ProLiant DL14x-series servers, functioning as the cluster's compute nodes.
8.
A 24-port ISR 9024 InfiniBand interconnect from Voltaire. This component provides the
high-speed message-passing interface (MPI) network.
Components not shown in
3
4
5
7
6
8
5
DL140 G2
LO100i
DL140 G2
6
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
7
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
LO100i
DL140 G2
8
LO100i
DL140 G2
LO100i
PORT 22
PORT 23
PORT 24
PORT 10
PORT 11
PORT 12
Figure
4-2, which shows the port side of the switch, to illustrate
Figure 4-2
include:
4.2 CPE with Rack-Mountable Servers — 22U Rack Configuration
2
hp
ProLiant
DL380 G4
1
2
UID
57

Advertisement

Table of Contents
loading

Table of Contents