D.16 One C7000 Enclosure With Double-Density Server Blades And The Hp Blc 4X Ddr Infiniband Gen2 Switch (No External Infiniband Switch) - HP Cluster Platform Express v2010 Overview

Workgroup system and cluster platform express overview and hardware installation guide
Hide thumbs Also See for Cluster Platform Express v2010:
Table of Contents

Advertisement

From
IB Switch 2 24 Port
Switch Port 16
IB Switch 2 24 Port
Switch Port 17
IB Switch 2 24 Port
Switch Port 18
IB Switch 2 24 Port
Switch Port 19
IB Switch 2 24 Port
Switch Port 20
IB Switch 2 24 Port
Switch Port 21
IB Switch 2 24 Port
Switch Port 22
IB Switch 2 24 Port
Switch Port 23
IB Switch 2 24 Port
Switch Port 24
D.16 One c7000 Enclosure with Double-Density Server Blades and the
HP BLc 4X DDR InfiniBand Gen2 Switch (No External InfiniBand Switch)
The following table specifies the wiring for a configuration for one c7000 enclosure with
double-density server blades and using two HP BL4c 4X DDR InfiniBand Gen2 switches wired
together. If the control node is a server blade, Port 16 of the InfiniBand switch installed in
Interconnect Module Bay 5/6 is wired to Port 16 of the InfiniBand switch installed in Interconnect
Module Bay 7/8.
If the configuration includes an external control node that is attached to the InfiniBand fabric,
the InfiniBand HCA in the control node is connected to Port 16 of the InfiniBand switch installed
in Interconnect Module Bay 5/6 and Port 16 of the InfiniBand switch installed in Interconnect
Module Bay 7/8 is left unconnected.
From
Enclosure 1
Interconnect
Module 5/6 Port 1
Enclosure 1
Interconnect
Module 5/6 Port 2
Enclosure 1
Interconnect
Module 5/6 Port 3
Enclosure 1
Interconnect
Module 5/6 Port 4
Enclosure 1
Interconnect
Module 5/6 Port 5
D.16 One c7000 Enclosure with Double-Density Server Blades and the HP BLc 4X DDR InfiniBand Gen2 Switch (No External
Label
To
Enclosure 2 Interconnect
IB-SW2-P16
Module 5/6 Port 16
Enclosure 3 Interconnect
IB-SW2-P17
Module 5/6 Port 9
Enclosure 3 Interconnect
IB-SW2-P18
Module 5/6 Port 10
Enclosure 3 Interconnect
IB-SW2-P19
Module 5/6 Port 11
Enclosure 3 Interconnect
IB-SW2-P20
Module 5/6 Port 12
Enclosure 3 Interconnect
IB-SW2-P21
Module 5/6 Port 13
Enclosure 3 Interconnect
IB-SW2-P22
Module 5/6 Port 14
Enclosure 3 Interconnect
IB-SW2-P23
Module 5/6 Port 15
Enclosure 3 Interconnect
IB-SW2-P24
Module 5/6 Port 16
Label
To
Enclosure 1 Interconnect
E1-IMB5-P1
Module 7/8 Port 1
Enclosure 1 Interconnect
E1-IMB5-P2
Module 7/8 Port 2
Enclosure 1 Interconnect
E1-IMB5-P3
Module 7/8 Port 3
Enclosure 1 Interconnect
E1-IMB5-P4
Module 7/8 Port 4
Enclosure 1 Interconnect
E1-IMB5-P5
Module 7/8 Port 5
Label
Comment
E2-IMB5-P16
E3-IMB5-P9
E3-IMB5-P10
E3-IMB5-P11
E3-IMB5-P12
E3-IMB5-P13
E3-IMB5-P14
E3-IMB5-P15
E3-IMB5-P16
Label
Comment
E1-IMB7-P1
E1-IMB7-P2
E1-IMB7-P3
E1-IMB7-P4
E1-IMB7-P5
InfiniBand Switch)
101

Advertisement

Table of Contents
loading

Table of Contents