From
ProCurve 2824
Port 21
ProCurve 2824
Port 22
ProCurve 2824
Port 23
ProCurve 2824
Port 24
D.7 One c7000 Enclosure with Single-Density Blades and an HP 4x DDR
InfiniBand Switch Module
The following table specifies the wiring scheme for a configuration of one c7000 enclosure with
single-density server blades using the HP 4x DDR InfiniBand switch module. The table shows
the optional connections for an external control node attached to the InfiniBand fabric and for
an external InfiniBand switch that may be included to provide InfiniBand fabric management.
If either of these components are not present in the configuration or if the control node is not to
be connected to the InfiniBand fabric, the associated connections are omitted.
c7000 Enclosure Wiring
From
Enclosure 1
Interconnect
Module 5/6 Port
1
Enclosure 1
Interconnect
Module 5/6 Port
2
Enclosure 1
Interconnect
Module 5/6 Port
3
Enclosure 1
Interconnect
Module 5/6 Port
4
Enclosure 1
Interconnect
Module 5/6 Port
5
Enclosure 1
Interconnect
Module 5/6 Port
6
86
Cabling Tables for CPE BladeSystem, with c7000 Enclosure Configurations
Label
To
Enclosure 1 OA1
Admin-ES1-P21
OA/ILO
Optional External
Admin-ES1-P22
Control Node NIC1
InfiniBand Switch 1
Admin-ES1-P23
Management Port
Optional external
Admin-ES1-P24
control node iLO
Label
To
InfiniBand 24-port
E1-IMB5-P1
Switch Port 1
E1-IMB5-P2
E1-IMB5-P3
E1-IMB5-P4
E1-IMB5-P5
E1-IMB5-P6
Label
E1-OA1-ILO
Control- NIC1
IB-SW1-NIC
Control-iLO
Label
IB-SW1-P1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Comment
Only Ppresent if control node is not
a server blade
Only used when an external
managed InfiniBand switch is
present
Optional connection
Comment
Only present if using a managed
24-port switch for Subnet
Management instead of a Host-Based
Subnet Manager

Advertisement

Table of Contents
loading

Table of Contents