Heat Exchanger Specifications - YASKAWA VS-626M5 Instruction Manual

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Appendix

15.5.2 Heat Exchanger Specifications

15.5.2 Heat Exchanger Specifications
15
To improve the cooling abilities of the control panel, install one of the Heat Exchangers (manufactured
by Yaskawa) shown in Table 15.8.
Table 15.7
Heat Exchanger Specifications
Heat Exchanger
Cooling Ability
REX1550
110 W/10°C (50°F)
HEATEX02
250 W/10°C (50°F)
The calorific content of the Cooling Ability column is the calorific tolerance when the internal air tempera-
ture rise within the unit is suppressed to 10 K (10 °C (50°F)) max.
Mount the heat exchanger internally as shown in Fig. 15.28 so that the internal air is drawn in from the
top and expelled through the bottom, and so that the external air is drawn in from the bottom and expelled
from the top.
Internal air
flow
External air
flow
Heat exchanger
Fig 15.28
Example of Heat Exchanger Mounting
Dimensions
(mm (inches))
295 x 890 x 50 (11.6 x 35 x 1.97)
(W x H x D)
440 x 924 x 50 (17.3 x 36.4 x 1.97)
(W x H x D)
Top
Case
Bottom
15 -24
Mounting Surface
2
(m
)
0.31
0.45

Hide quick links: