Wiring Control Circuit Signals; Control Signal Connectors And Wires - YASKAWA VS-626M5 Instruction Manual

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Wiring

3.4.1 Control Signal Connectors and Wires

3.4 Wiring Control Circuit Signals

3.4.1 Control Signal Connectors and Wires
3
Control PC
Board
(VS-626M5)
(VS 626M5)
I/O Card
(VS-626M5)
(stand-alone
drives only)
YENET1200
Card
(VS-626M5)
(NC systems
only)
Encoder
Method
Orientation
Orientation
Card
(VS-626M5)
Magnetic
Sensor Meth-
od Orientation
Card
(VS-626M5)
To reduce the influence of noise on control circuit signals, the control signal lines must be separated from power
lines and wired at the shortest distance (20 m max.). Do not wire the control signal lines together with power
lines in the same conduit or bundle them together, or otherwise the system may malfunction.
Table 3.10 outlines the relationship between control signal connectors and wires to be used in combination.
Table 3.11 outlines wires that are applicable to connectors.
Table 3.10
Control Signal Connectors
Con-
nector
nector
Function
Function
No.
Inverter Side
Control signal
51CN
connector with
(34P)
converter unit
8830E 068
8830E-068-
170LD-32
Control signal
52CN
connector with
(34P)
other drive unit
1CN
Control signals
10236-52A2JL
(36P)
2CN
Encoder signal
10220-52A2JL
(20P)
input
3CN
Digital operator
10214-52A2JL
(14P)
6CN
Control signals
10250-52A2JL
(50P)
4CN
Control signals
MR-8RMAG
(8P)
Load shaft
8CN
encoder signal
10220-52A2JL
(20P)
input
Load shaft
9CN
encoder signal
10214-52A2JL
(14P)
output
10CN
Control signals
10214-52A2JL
(14P)
Connector Type
Connector Pin
Connector Pin
Wiring Side
34
32
8822E-034-171D
8822E 034 171D
4
2
S 10136-
36
3000VE
S ·10336-
52A0-008
19
(case)
S 10120-
20
3000VE
S 10320-
52A0-008
11
(case)
S 10114-
14
3000VE
S 10314-
52A0-008
8
(case)
S 10150-
50
3000VE
S 10350-
52A0-008
26
(case)
MR-8LFG
S 10120-
20
3000VE
S 10320-
52A0-008
11
(case)
S 10114-
14
3000VE
S 10314-
52A0-008
8
(case)
S 10114-
14
3000VE
S 10314-
52A0-008
8
(case)
3 -24
Applica-
ble Max.
ble Max.
Connector
Connector
Wire
Nos.
Manufacturer
Size
33
31
Use a
special
special
KEL Corp.
KEL Corp
cable.
3
1
18
0.2
Sumitomo 3M
2
mm
Ltd.
1
10
0.2
Sumitomo 3M
2
mm
Ltd.
1
7
Use a
Sumitomo 3M
special
Ltd.
cable.
1
25
0.2
Sumitomo 3M
2
mm
Ltd.
1
3
8
0.25
Honda Tsushin
5
2
7
2
4
mm
Kogyo Co., Ltd.
1
6
10
0.2
Sumitomo 3M
2
mm
Ltd.
1
7
0.2
Sumitomo 3M
2
mm
Ltd.
1
7
0.2
Sumitomo 3M
2
mm
Ltd.
1

Hide quick links: