YASKAWA VS-626M5 Instruction Manual page 144

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Orientation Control Using an Encoder
8.7.3 Details of the Stop Position Reference Signal
INFO
8
Signal
Pin Number
D1
19
D2
20
D3
21
D4
22
D5
23
D6
24
D7
25
D8
26
D9
27
D10
28
D11
29
D12
30
When using signed binary data, the meaning of the signal will depend on the sign (+ or −).
D
If the sign is positive, the total number of bit pulses input is added:
0 0 1 0 1 0 0 1 0 0 1
:
:
256+ 64
+
If the sign is negative, the negative of sum of the number of bit pulses input is used:
− (256 + 64 + 3 + 1) = −329
For incremental operations, binary references cannot be above 180_. For BCD references, references
D
above 180_ are possible depending on the setting of the BCD stop position reference resolution C2-12
(P
) to a maximum of ±360_.
BCD
The input signal circuit for the stop position reference for the Encoder orientation is the same as that shown
in 3.4.4 Sequence Input Signal Circuits.
Without Sign
1
2
4
8
16
32
64
128
256
512
1024
2048
:
:
8
1
= 329
+
8-10
Binary
With Sign
With Sign
1
1
2
2
4
4
8
8
16
10
32
20
64
40
128
80
256
100
512
200
1024
400
Sign
Sign
BCD

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents