YASKAWA VS-626M5 Instruction Manual page 43

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

The following shows standard connections of the VS-626M5 with peripheral units.
Power Supply:
200 VAC,
Single-phase
Molded-case Circuit
Breaker (2MCCB) or
Ground Fault
Interrupter
Magnetic Contactor
*2
(2MC)
VS-656MR5
(Converter)
Grounding
*1
Make sure to connect an AC reactor to each Converter. Do not connect any equipment
other than the Converter to the secondary side of the AC reactor. If not observed, Con-
verter may burn out.
*2
Connect a surge absorber to the electromagnetic contactor in parallel with the coil of the
electromagnetic contactor, or otherwise the control signal lines may malfunction.
Fig 3.1
Power Supply:
200 VAC, 3-phase (200 V Class) or
400 VAC, 3-phase (400 V Class)
Molded-case Circuit
Breaker (1MCCB) or
Ground Fault
Interrupter
Input Noise Filter
Magnetic Contactor
*2
(1MC)
AC Reactor (L)*
R/L1
S/L2
A1/r
T/L3
A2/t
Connection Bus Bar
Flat Cable
P1N1 Power Supply Cable
Grounding
Connection with Peripheral Units for External Heatsink Cooling Type
3 -3
3.1 Connection with Peripheral Units
1
VS-626M5
(Inverter)
U/T1
V/T2
Encoder Cable
W/T3
Z1, Z2, Z3
Motor Cooling Fan
Motor
Power Supply
3
Molded-case
Circuit Breaker
(3MCCB)
or
Ground Fault
Interrupter