YASKAWA VS-626M5 Instruction Manual page 235

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Rated Output kW
30 min.
Continuous
Q
Rating
Rating
*1
3.7
2.2
60
(2.36)
5.5
3.7
60
(2.36)
7.5
5.5
80
(3.15)
11
7.5
110
(4.33)
15
11
110
(4.33)
18.5
15
110
(4.33)
22
18.5
110
(4.33)
30
22
140
(5.51)
37
30
140
(5.51)
*2
45
37
140
(5.51)
* 1. 3.7/2.2 kW is 15 min. rating (50% ED)/Continuous rating. There are no eyebolts on the 3.7/2.2 kW or 5.5/3.7 kW models.
* 2. 45/37 kW is for the 400 V Series.
Notes:1. The shaft key and the key way are standard JIS B 1301-1996 models.
2. External dimensions are the same for both the 200 V and 400 V Series.
Shaft Dimensions
QK
QR
S
T
45
1
7
+0.009
28
(1.77)
(0.039)
(0.28)
−0.004
45
1
7
0
28
(1.77)
(0.039)
(0.28)
−0.013
70
1
8
0
32
(2.76)
(0.039)
(0.31)
−0.016
90
0.5
9
0
48
(3.54)
(0.02)
(0.35)
−0.016
90
1
9
0
48
(3.54)
(0.039)
(0.35)
−0.016
90
1
9
0
48
(3.54)
(0.039)
(0.35)
−0.016
90
1
10
+0.030
55
(3.54)
(0.039)
(0.39)
+0.011
110
2
11
+0.030
60
(4.33)
(0.079)
(0.43)
+0.011
110
2
11
+0.030
60
(4.33)
(0.079)
(0.43)
+0.011
110
1
12
+0.030
70
(4.33)
(0.039)
(0.47)
+0.011
14 -31
14.2 Standard Motor Specifications
U
W
d
m
4
8
16
M6
(0.16)
(0.31)
(0.63)
4
8
22
M4
(0.16)
(0.31)
(0.87)
5 (0.2)
10
22
M5
(0.39)
(0.87)
5.5
14
40
M5
(0.22)
(0.55)
(1.57)
5.5
14
40
M5
(0.22)
(0.55)
(1.57)
5.5
14
40
M5
(0.22)
(0.55)
(1.57)
6
16
45
M5
(0.24)
(0.63)
(1.77)
7
18
50
M6
(0.28)
(0.71)
(1.97)
7
18
50
M6
(0.28)
(0.71)
(1.97)
7.5
20
60
M6
(0.3)
(0.79)
(2.36)
14

Hide quick links:

Advertisement

Table of Contents
loading