YASKAWA VS-626M5 Instruction Manual page 207

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

*1
Model CIMR-M5j
Continuous Rated Input Cur-
rent (A)
Continuous Rated Output Cur-
rent (A)
Control Method
Speed Control Range
Speed Regulation
Overload Capacity
Approx. Mass
lb (kg)
Width
Dimensions in
inches
inches
Height
*2
2
(mm)
(mm)
Depth
1
Model CIMR-MR5j*
Required Power Capacity
(kVA)
Continuous Rated Input Cur-
rent (A)
Continuous Rated Output Cur-
rent (A)
Power Supply
Control Power Supply
Control Method
Overload Capacity
Approx. Mass
lb (kg)
Width
Dimensions in
inches
inches
Height
*2
2
(mm)
(mm)
Depth
Power Supply AC Reactor
Code No.
*1
Model CIMR-M5j
*1
CIMR-MR5j
Ambient Temperature
Heatsink Intake Air Tempera-
ture
*4
Storage Temperature
Humidity
Location
Vibration
Protective Structure
* 1. A: For stand-alone drive system N: for NC system
* 2. Dimensions of External Heatsink Cooling Type. Refer to 14.1.3 Dimensions for Open Chassis Type.
* 3. An AC reactor is required between Converter and main circuit power supply.
* 4. Temperature during shipping.
23P7
23P5
27P5
17.6
17.6
26.2
21
21
31
Sine wave PWM Inverter (Vector control)
11 (5)
3.94 (100)
23P7
25P5
27P5
7
9
12
13.3
13.3
19.7
17.6
17.6
26.2
Three-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%,
Line-to-line voltage unbalance: 5% or less)
Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%)
Required power capacity: 100 VA (for independent drive system)
Power regenerative control (120_ current conduction)
120% for one minute, 200% for one second
11 (5)
3.94 (100)
X010057
X010058
X010059
23P7
25P5
27P5
0°C to 55°C (32°F to 131°F) (not frozen)
Indoor (protected from corrosive gases and dust), elevation: 1000 m (3280 ft) or less
2
9.8 m/s
(1G) at 10 to less than 20 Hz, up to 2 m / s
(Protected so that parts of the human body cannot reach electrically charged parts from the front)
14 -3
2011
2015
2018
35.7
52.4
71.4
40
56
80
−1
40 min
to maximum motor speed
0.2% maximum speed or less
120%, 60s of 30-minute rating
27 (12)
5.91 (150)
13.78 (350)
12.60 (320)
2011
2015
2018
19
24
30
26.8
39.3
53.6
35.7
52.4
71.4
250 VA (for NC system)
27 (12)
5.91 (150)
13.78 (350)
12.60 (320)
X010060
X010061
X010062
2011
2015
2018
0°C to 45°C (32°F to 113°F)
−20°C to 60°C (−4°F to 140°F)
90% or less (non-condensing)
2
(0.2G) at 20 to 50 Hz
IEC IP00
14.1 Drives
2022
2030
2037
88.1
104.8
142.8
98
113
160
35 (16)
57 (26)
7.84
11.81
(200)
(300)
2022
2030
2037
36
48
60
66.1
78.6
107.2
88.1
104.8
142.8
35 (16)
57 (26)
7.84
11.81
(200)
(300)
X010063
X010064
X010120
2022
2030
2037
14

Hide quick links:

Advertisement

Table of Contents