Digital Operator Operation Mode - YASKAWA VS-626M5 Instruction Manual

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Operating the Digital Operator

5.3.5 Digital Operator Operation Mode

IMPORTANT
5.3.5 Digital Operator Operation Mode
5
The following are constants that cannot be changed during operation:
C1-25 to 59, C2-09 to 27, C3-09 to 25: Cannot be changed during operation. Change when
C1-01 to 24, C2-01 to 08, C3-01 to 08: Can be changed during operation or when stopped.
In Digital Operator operation mode, operation is enabled by commands from the Digital Operator. The
following table shows the operation. Change the lower 2 bits of C1-37 from "
operation mode.
Description
S C1-37 is selected.
S Display C1-37 data con-
tents.
S Select the digit of bit 1
(second place from the
right).
S Change set value. (Turn
ON lower two bits.)
S Write-in set value.
S Press DATA/ENTER Key
until "End" is displayed.
S Return to control
constants display.
The following table shows the reference list in Digital Operator operation. Operation control signals (se-
quence input) and speed references displayed among reference display are handled similar to constant set-
up.
Table 5.2
Parameters for Digital Operator Operations
Constants No.
Operation signal
(Sequence input)
Speed reference
stopped.
Key
Digital Operator Display
Sequence
DATA
ENTER
RESET
RESET
DATA
ENTER
DSPL
Name
Unit
Binary
%
5 -8
" to "
" to turn ON the
Remarks
Displayed for 0.5 sec.
Returns to previous display
before write-in.
Effective for Digital Operator
operation mode.
Contents
Bit
9 8 7 6 5 4 3 2 1 0
Displayed in % for rated speed setting (C1-26)
TLH
TLL
SSC
− − −
CHW
PPI
ORT
LGR
MGR
− − −

Hide quick links: