YASKAWA VS-626M5 Instruction Manual page 54

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Wiring
3.3.2 Functions of Main Circuit Terminals
3
Table 3.9
Inverter Main Circuit Terminals
Voltage
Symbol
Class
P/¨
N/©
P1
N1
A12/r2*
200 V
A22/t2
class
U/T1
V/T2
W/T3
P/¨
N/©
P1
N1
A12/r2*
400 V
A22/t2
class
U/T1
V/T2
W/T3
*
Terminals on Open Chassis Inverters with a minimum capacity of 11 kW.
Name
270 to 325 VDC
Main circuit power supply
input
(Supplied from converter)
282 to 325 VDC
Control power supply
input
(Supplied from converter)
Single-phase
Heatsink
Power supply input for
cooling fan
Inverter output
Inverter output to motor
Ground terminal
Grounding
(Ground resistance: 100 Ω or less)
540 to 650 VDC
Main circuit power supply
input
(Supplied from converter)
282 to 325 VDC
Control power supply
input
(Supplied from converter)
Single-phase
Heatsink
Power supply input for
cooling fan
Inverter output
Inverter output to motor
Ground terminal
Grounding
(Ground resistance: 10 Ω or less)
3 -14
Functions
200 to 220 VAC 50 Hz
200 to 230 VAC 60 Hz
200 to 220 VAC 50 Hz
200 to 230 VAC 60 Hz