YASKAWA VS-626M5 Instruction Manual page 174

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Con-
Name
stant
No.
Magnetic Pole
Adjusts the position of the magnetic pole. Sets the difference between the
magnetic position and the encoder origin signal using the electrical angle
Positioning
(360_ el = 8192). Set the C1-60 value on the terminal box.
(360_ el = 8192). Set the C1-60 value on the terminal box.
* 6
* 6
C1 60
C1-60
Value
Value
When the setting has changed, turn the control power supply OFF then
ON again.
Phase-C Pulse
Sets the pulse width of the motor encoder origin signal (phase C). Set the
* 6
Width
C1-61 value listed on the terminal box.
C1 61
C1-61
When the setting has changed, turn the control power supply OFF then
ON again.
*1. Change (change during operation) column: Indicates whether the constant can be changed during inverter operation.
Yes: Constant can be changed during inverter operation; No: Constant cannot be changed during inverter operation
*2. This constant is enabled for stand-alone drives (M5A) only. Do not change the set value for NC system s (M5N).
*3. Connector pin numbers are for stand-alone drives.
*4. In signal selection descriptions, 0 stands for "
*5. This function is available in the following software.
VSM200XXX: VSM200112 or later
*6. Constants only for IPM motors (with syncs using flush-type permanent magnets). C1-60 and C1-61 are not displayed when the
software for controlling an induction motor is used.
User Constants (continued)
Table 10.1
Explanation
" and 1 for "
10-7
."
10.1 User Constants
Change
Unit
Standard
Upper
* 1
Setting
Limit/
Lower
Limit
8191
No
No
---
4096
4096
−8192
100
No
No
Pulse
Pulse
7
7
0
10