Fault Record Display Mode - YASKAWA VS-626M5 Instruction Manual

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

5.3.7 Fault Record Display Mode

Up to six faults can be displayed in order from most recent to oldest.
Display Example
42 occurred
D
D
D
D
D
D
IMPORTANT
S Fault record data are not erased by fault reset or turning OFF power supply. (The data will not affect
S To erase fault record data, turn ON bit 0 of C1-57 (right end) and turn OFF the control power supply.
Fault No.
Fault Occurrence No. (1 to 6)
The larger the number, the older the fault data.
30 occurred
E4 occurred
(6AL)
(5AL)
(4AL)
Displays the last fault No.
Displays the second most recent fault No.
Displays the third most recent fault No.
Displays the fourth most recent fault No.
Displays the fifth most recent fault No.
Displays the sixth most recent fault No.
the operation.)
When power is turned ON again, data will be erased and bit 0 of C1-57 will automatically be turned
OFF.
5 -11
E0 occurred
E1 occurred
01 occurred
(3AL)
(2AL)
(1AL)