Fault Display And Troubleshooting; Checking Of Causes - YASKAWA Varispeed-606PC3 Instruction Manual

Ultra-compact all-digital low-noise inverter
Table of Contents

Advertisement

1 . VS-606PC3 INVERTER MAIN UNIT (Cont'd)
1 .8 FAULT DISPLAY AND TROUBLESHOOTING
If a fault occurs and the inverter functions are lost,
check for the causes and provide proper corrective
actions, referring to the following checking method.
Contact your YASKAWA representative if any fault
other than described below occurs, if the inverter itself
malfunctions, if any parts are damaged, or if you have
any other problems . A list of the YASKAWA
representatives is available on the last page .
1 .8 .1 Checking of Causes
The inverter has protective functions to protect it from
faults such as overcurrent or overvoltage . If a fault
occurs, the protective functions operate to shut off the
inverter output and the motor coasts to a stop. At the
same time, the fault contact signal is output.
When the protective functions operate in models
with indicating cover, the digital display unit displays a
fault shown in Table 1 .8 .
Also when the digital
operator is used, the fault display is provided.
Operation can be restarted by turning ON the
fault reset input signal (or
='
key of the digital
E
R ESET
operator) or turning OFF the power supply and ON
again.