Keypad Operation

Digital Operator Display (optional)

The key names and functions of the Digital Operator are described below
-DRIVE-
U1-01 = 50.00Hz
Digital Operator Keys
Key
LOCAL/REMOTE Key
MENU Key
ESC Key
JOG Key
FWD/REV Key
Shift/RESET Key
Increment Key
Decrement Key
DATA/ENTER Key
RUN Key
STOP Key
Note: Except in diagrams, Keys are referred to the key names listed in the above table.
-Rdy-
Frequeny Ref
U1-02 = 50.00Hz
U1-03 = 10.50A
Name
Switches between operation via the Digital Operator (LOCAL) and the settings in
b1-01 and b1-02 (REMOTE).
This key can be enabled or disabled by setting parameter o2-01.
Selects menu items (modes).
Returns to the status before the DATA/ENTER key was pressed.
Starts jog operation when the inverter is operated by the Digital Operator and d1-18
is set to 0.
Selects the rotation direction of the motor when the Inverter is operated by the Digi-
tal Operator.
Sets the active digit when programming parameters.
Also acts as the Reset key when a fault has occurred.
Selects menu items, sets parameter numbers, and increments set values.
Used to move to the next item or data.
Selects menu items, sets parameter numbers, and decrements set values.
Used to move to the previous item or data.
Enters menus and parameters, and set validates parameter changes.
Starts the Inverter operation when the Inverter is controlled by the Digital Operator.
Stops Inverter operation.
This key can be enabled or disabled using parameter o2-02 when operating from a
source different than the operator.
Drive Status Indicators
FWD:
Lights up when a forward run command is input.
REV:
Lights up when a reverse run command is input.
SEQ:
Lights up when any other run command source
than the digital operator is selected
REF:
Lights up when any other frequency reference
source than the digital operator is selected
ALARM:Lights up when an error or alarm has
occurred.
Data Display
Displays monitor data, parameter numbers and param-
eter settings.
Mode Display (displayed at the upper left of data display)
DRIVE:
Lights up in Drive Mode.
QUICK:
Lights up in Quick Programming Mode.
ADV:
Lights up in Advanced Programming Mode.
VERIFY:
Lights up in Verify Mode.
A. TUNE:
Lights up in Autotuning Mode.
Keys
Execute operations such as setting parameters, moni-
toring, jogging, and autotuning.
Function