Configuration procedure
Follow these steps to enable GVRP on an Ethernet port:
To do...
Enter system view
Enable GVRP globally
Enter Ethernet port view
Enable GVRP on the port
After you enable GVRP on a trunk port, you cannot change the port to a different type.

Configuring GVRP Timers

Follow these steps to configure GVRP timers:
To do...
Enter system view
Configure the LeaveAll timer
Enter Ethernet port view
Configure the Hold, Join, and
Leave timers
Note that:
The setting of each timer must be a multiple of 5 (in centiseconds).
The timeout ranges of the timers vary depending on the timeout values you set for other timers. If
you want to set the timeout time of a timer to a value out of the current range, you can set the
timeout time of the associated timer to another value to change the timeout range of this timer.
The following table describes the relations between the timers:
Use the command...
system-view
gvrp
interface interface-type
interface-number
gvrp
Use the command...
system-view
garp timer leaveall
timer-value
interface interface-type
interface-number
garp timer { hold | join |
leave } timer-value
1-5
Remarks
Required
By default, GVRP is disabled globally.
Required
By default, GVRP is disabled on the port.
Remarks
Optional
By default, the LeaveAll timer is set
to 1,000 centiseconds.
Optional
By default, the Hold, Join, and Leave
timers are set to 10, 20, and 60
centiseconds respectively.